Industrial Micro SD Card
AP-MSDxxxIXX-T
12
© 2013 Apacer Technology, Inc. Rev. 1.0
3. Power Cycle Count
Value: To record power cycle condition.
Increasing this value by 1 when a power Cycle ( both normal and abnormal )
occurred.
Initial value = 0.
Maximum value = 4294967295.
4. Spare Block Count
Value: To record spare block counts.
Decreasing this variable when detected run-time bad blocks.
(Note:run-time bad blocks may be “erase error”, “program error”, “read error”.)
Initial value = depend on Flash.
Maximum value = 255.
Minimum value = 0.
5. ECC Uncorrectable Count
Value: To record ECC uncorrectable block counts.
Increase this value by 1 when fetal error occurred in Flash read operation.
Initial value = 0.
Maximum value = 255.
6. Flash Type
Value: To determinate mounted Flash type, and always keep in original value.
0: SLC, 1:MLC.
Initial value = depend on Flash.
7. Initial Bad Block Count
Value: To record initial bad blocks when MP process, and always keep in original value.
Initial value = depend on Flash.
Maximum value = 65535.
8. Later Bad Block Count
Value: To record run time bad blocks.
Increasing this variable when detected run-time bad blocks.
Initial value = 0.
Maximum value = 65535.
Simple User Interface Version:
Komentáře k této Příručce